19
CQM1-B7A03
Unused
Connect to the SIG terminal of
the output B7A Link terminal.
Connect to the negative power supply ter-
minal of the output B7A Link Terminal.
Connect to the SIG terminal of
the output B7A Link Terminal.
Connect to the negative power supply ter-
minal of the output B7A Link Terminal.
A
0
A
1
A
2
A
3
B
0
B
1
B
2
B
3
Word m
Word m + 1
CQM1-B7A12
Unused
Connect to the SIG terminal of
the input B7A Link terminal.
Connect to the negative power supply ter-
minal of the input B7A Link Terminal.
A
0
A
1
A
2
A
3
B
0
B
1
B
2
B
3
Word n
Unused
CQM1-B7A02
Unused
Connect to the SIG terminal of
the output B7A Link terminal.
Connect to the negative power supply ter-
minal of the output B7A Link Terminal.
A
0
A
1
A
2
A
3
B
0
B
1
B
2
B
3
Word m
Unused
Connectors Crimp connectors for I/O Unit wiring should be less than 6.2 mm wide (M3), and
the wire should be AWG22 to 18 (0.3 to 0.75 mm
2)
.
Terminal screws should be tightened with a torque of 0.5 N S m.
6.2 mm max.
6.2 mm max.
Caution Forked crimp connectors are required by UL and CSA standards.
Connections to B7A Link Terminals Section 3-1