63
Editing Parameters Section 3-1
IMPORTANT When the Safety Input Channel Mode is set to Test Pulse from Test Out, spec-
ify the test output to use for the test source and set the Test Output Channel
Mode of the test output to Pulse Test Output.
S Dual Channel Safety
Input Discrepancy Time
0 to 65,530 ms
(in 10-ms increments)
Sets the time to monitor the logic discrepancy
in the dual channel input logic.
0 ms
I/O Comment 32 characters max. Sets an I/O comment for the safety input. The
I/O comment set here is used as the I/O tag in
the Logic Editor.
None
Maintenance Counter
Mode Choice
Time (cumulative ON
time monitor)
Sets the operating mode for the maintenance
counter.
Time
Count (contact opera-
tion counter)
Threshold Mainte-
nance Counter
0 to 4,294,967,295
hours
Sets the threshold value for the maintenance
counter.
0
Item Settings Description Default