66
Editing Parameters Section 3-1
3-1-7 Operation Time Parameter Groups
This section describes parameters in the safety input/output operation time
groups. The operation time parameters are grouped by the terminal numbers
to be paired.
Note Safety input parameter groups can be set for DST1-XD0808SL-1 safety inputs
IN0 to IN5. For details on DST1-XD0808SL-1 logic functions, refer to 1-5
Logic Functions.
Item Settings Description Default
Equipment Name 32 characters max. Sets a comment for the operation time to
monitor.
None
Threshold Response
Time
0 to 65,535 ms
(in 1-ms increments)
Sets the threshold value for the operation
time.
0 ms