X
Revision History
The revision code of this manual is given at the end of the catalog number at the
bottom left of the back cover. The following table outlines the changes made to the
manual during each revision. Page numbers refer to the previous version.
Cat. No. Z182-E1-03
Revision code Date Pages and changes
01 May 2003 Original production
02 February 2004 The following changes were made. Other changes were also made to improve general quality.
Introduction: Descriptions mainly on precautionary information updated.
Page 1-5: “Bar graph” added to the top list.
Page 1-6: “Function key 1” added to the “Auto/Manual key.
Page 1-7: Note at the bottom of the page corrected.
Page 1-8: Event input assignment diagram corrected.
Page 1-10: Control/transfer output allocation diagram corrected.
Page 1-12: Item 11 corrected to “Communications method.
Pages 2-4 to 2-7: Terminal arrangement graphics corrected.
Page 2-8: Paragraph below the table deleted.
Page 2-9: Note added below the table.
Page 2-10: E5ER graphic on the right side deleted and “E5ER” on the left graphic changed to
“E5ER-@4@@.”
Page 2-11: “Event inputs 3 to 7” corrected to “event inputs 3 to 6” in two paragraphs under
Event inputs (terminals).
Page 3-11 (and throughout the manual): “Control initial setting level 2” corrected to “Control
initial setting 2 level.
Page 3-16: The RSP indicator in the graphic under RUN level (Ch 2) corrected to OFF from ON.
Page 4-7: “PID adjustment levelcorrected to “PID setting level.
Page 4-22: Auxiliary output assignment diagram corrected.
Page 4-25: Item 8 “Press the level key twice” corrected to “Press the level key three times.
Page 4-31: Item (1) “About two seconds” corrected to “About four seconds.
Page 5-9: Monitor and setting range for SP ramp time unit in the top table corrected.
Page 5-30: “Auto/Manual (Adjustment level)” corrected to “Auto/Manual (RUN level)” under
Auto/Manual.
Page 8-12: DOTC: Disturbance time constant under Adjustment level corrected to “0.01-99.99.
Pages 8-15, 8-16, 8-19, 8-27, 8-31, and 8-32: “PID Set No.corrected to “PID.
Page 8-26: The seven segment display (7.LSP) at the right top placed in a white box.
Page 8-35: Description added to RSPH and RSPL in the bottom graphic.
Page 8-46: Description under Setting range in the top table corrected.
Page 8-49: The second “Cascade standard control” in the bottom table corrected to “Cascade
heating/cooling control.
Page 8-51: The default value under straight-line approximation corrected from ON to OFF.
Page A-2: Note 3 added below the Unit Ratings table.
Page A-2:Outflow current: Approx. 7 mA” under Unit ratings corrected to “Short-circuit current:
Approx. 4 mA.
Page A-3: “(
±5% FS)± digit or less” under Indication accuracy corrected to “(±5% FS)± 1 digit
max.
Page A-3: “0.2 to 99.9 seconds” under Control period corrected to “0.2 to 99.0 seconds.
Page A-3: “Acceleration: 10 m/s
2
” under Vibration tolerance corrected to “Acceleration: 20 m/
s
2
.”
Page A-19: Description under Setting (monitor) value for 0E0C corrected.
Page A-20: Description under Setting (monitor) value for 0E20 corrected.
Page A-22: The second “Cascade standard control” in the table corrected to “Cascade heating/
cooling control.
Page A-30: DOTC: Disturbance time constant under Adjustment level corrected to “0.01-99.99.
02A November 2004 The following changes were made.
Page A-3: Information was added to the table and accompanying notes.