Appendix
A-14
Appendix
CompoWay/F
Setting data
Attributes
Variable type
Address Address
Modbus
Character Setting (monitor) value Character
Default
value
Decimal point
position
Units
Set value
C9
0000
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
001C
002A
0038
0046
0054
0062
006F
0900
0902
0904
0906
0908
090A
090C
090E
0910
0912
0914
0916
0918
091A
091C
0938
0954
0970
098C
09A8
09C4
09DE
d.bnk
0.lsp
0.pid
0.al-1
0.al1h
0.al1l
0.al-2
0.al2h
0.al2l
0.al-3
0.al3h
0.al3l
0.al-4
0.al4h
0.al4l
1.lsp
2.lsp
3.lsp
4.lsp
5.lsp
6.lsp
7.lsp
7.al4l
0 to 7
SP setting lower limit to SP setting upper limit
H'00000000 to H'00000008 (0 to 8 (0: Auto selection) )
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
H'FFFFB1E1 to H'0001869F (-19999 to 99999)
The following is the same as Bank 0
0 to 7
Same as at left
0 to 8
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
-19999
to
99999
*1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
EU
EU
EU
EU
EU
EU
EU
EU
EU
EU
EU
EU
EU
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
According to input type
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
Display bank selection
Bank 0 local SP (LSP)
Bank 0 PID set number
Bank 0 alarm value 1
Bank 0 alarm upper limit 1
Bank 0 alarm lower limit 1
Bank 0 alarm value 2
Bank 0 alarm upper limit 2
Bank 0 alarm lower limit 2
Bank 0 alarm value 3
Bank 0 alarm upper limit 3
Bank 0 alarm lower limit 3
Bank 0 alarm value 4
Bank 0 alarm upper limit 4
Bank 0 alarm lower limit 4
Bank 1 local SP (LSP)
~
Bank 2 local SP (LSP)
~
Bank 3 local SP (LSP)
~
Bank 4 local SP (LSP)
~
Bank 5 local SP (LSP)
~
Bank 6 local SP (LSP)
~
Bank 7 local SP (LSP)
~
Bank 7 alarm lower limit 4
Bank setting level
*1 .... Bank number selected for execution.
"H' -" indicated in set values (monitor values) are values set by communication (monitor).