Setting list
A-27
Appendix
CompoWay/F
Setting data
Attributes
Variable type
Address Address
Modbus
Character Setting (monitor) value Character
Default
value
Decimal point
position
Units
Set value
D3 0000
0001
0002
0003
0004
0005
0006
0007
0008
000A
000B
000C
000D
000E
000F
0010
0011
0012
0013
0018
0019
1300
1302
1304
1306
1308
130A
130C
130E
1310
1314
1316
1318
131A
131C
131E
1320
1322
1324
1326
1330
1332
p-on
sptr
pidi
pidh
p-db
cjc.1
cjc.2
cjc.3
cjc.4
alfa
p tr
mant
mani
orlm
at-g
at-h
lcma
tate
rbmp
pmec
dost
H'00000000: Continue: CONT (0)
H'00000001: Stop: STOP (1)
H'00000002: Manual mode: MANU (2)
H'00000000: Off: OFF (0)
H'00000001: On: ON (1)
H'00000000: PV (0)
H'00000001: DV (1)
H'0000000A to H'0000270F (0.10 to 99.99)
H'00000000 to H'0001869F (0 to 99999)
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000000 to H'00000064 (0.00 to 1.00)
H'00000000: Off: OFF (0)
H'00000001: On: ON (1)
H'00000000: MV hold: HOLD (0)
H'00000001: Default value output: INIT (1)
Standard: H'FFFFFFCE to H'0000041A (-5.0 to 105.0)
Heat/cool: H'FFFFFBE6 to H'0000041A (-105.0 to
105.0)
H'00000000: Mode 0: 0
H'00000001: Mode 1: 1
H'00000001 to H'00000064 (0.1 to 10.0)
H'00000001 to H'00000063 (0.1 to 9.9)
H'00000032 to H'000001F4 (5.0 to 50.0)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000000: Disabled: OFF (0)
H'00000001: Enabled: ON (1)
H'00000000: Disabled: OFF (0)
H'00000001: Enabled: ON (1)
H'00000000: Disabled: OFF (0)
H'00000001: Enabled: ON (1)
cont, stop,
manu
off, on
p , d
0.10 to 99.99
0 to 99999
off, on
off, on
off, on
off, on
0.00 to 1.00
off, on
hold, init
-5.0 to 105.0
-105.0
to
105.0
0, 1
0.1 to 10.0
0.1 to 9.9
5.0 to 50.0
0.0 to 100.0
off, on
off, on
off, on
CONT
OFF
PV
0.50
0
ON
ON
ON
ON
0.65
OFF
HOLD
0.0
0
1.0
0.2
20.0
10.0
OFF
OFF
OFF
%FS
EU
%
%FS
%
%FS
2
According to input type
2
1
1
1
1
1
CH
CH
CH
CH
CH
Common
Common
Common
Common
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
Operation at power on
SP tracking
PID set automatic selection data
PID set automatic selection hysteresis
PV dead band
Input 1 cold junction
compensation
Input 2 cold junction
compensating system
Input 3 cold junction
compensation
Input 4 cold junction
compensation
α
PV tracking
Manual output method
Manual MV initial value
MV change rate limit mode
AT calculated gain
AT hysteresis
Limit cycle MV amplitude
Temporary A.T. excitation judgement deviation
Bump-less at RUN
Operation at poteniometer
input error
Disturbance overshoot
adjustment function
Expansion control setting level
"H' -" indicated in set values (monitor values) are values set by communication (monitor).