Setting data list
A-31
Appendix
d.bnk
Display bank selection
0
Bank 0
Bank 1
Bank 2
1
2
7
Bank 7
D
U
M
0.lsp
0.al-1
0.al1h
0.al1l
0.0
0
0.0
0.0
0.0
M
M
M
M
0.pid
M
M
0.al4l
0.0
7.lsp
7.al-1
7.al1h
7.al1l
0.0
0
0.0
0.0
0.0
M
M
M
M
7.pid
M
M
7..al4l
M
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
0.0
d.pid
Display PID selection
1
PID1
PID2
PID3
2
3
8
PID8
D
U
M
M
M
M
M
M
M
M
M
M
1.p
10.00
1.i
233.0
1.d
40.0
1.ol-h
100.0
1.ol-l
0.0
M
1.aut
1450.0
8.p
10.00
8.i
233.0
8.d
40.0
8.ol-h
100.0
8.ol-l
0.0
M
M
M
8.aut
1450.0
l.pid
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
0.000
fi01.1
0.000
M
si2.1
si1.1
so1.1
so2.1
1.000
0.000
1.000
0.000
M
M
M
fi20.1
M
fo01.1
fo20.1
M
M
si2.2
si1.2
so1.2
so2.2
1.000
0.000
1.000
0.000
M
M
M
0.000
0.000
0.000
l.tec
l.bnk
L
LL
L
L
key 1 second or more
Control starts
Adjustment
level
Protect level
Operation
Level
Adjustment 2
level
PID setting
level
Bank setting
level
Approximation
setting level
Control initial
setting level
Input initial
setting level
Control initial
setting 2 level
Display adjustment
level
Alarm setting
level
Communication
setting level
Special function
setting level
Expansion control
setting level
Power on
Bank Setting
Level
less than
1 second
less than 1 second
PID Setting
Level
Approximation
Setting Level
less than 1 second
less than
1 second
7. LSP: Bank 7 LSP
SP lower limit
_SP upper limit
7. AL-1: Bank 7
Alarm value 1
-19999-99999
7. AL1H: Bank 7
Alarm upper limit 1
-19999-99999
7. AL1L: Bank 7
Alarm lower limit 1
-19999-99999
7. AL4L: Bank 7
Alarm lower limit 4
-19999-99999
7. PID: Bank 7
PID set nunmer
0-8
8.P: PID8
Proportional band
0.00-999.99 (standard) 1
8.I: PID8 Integral time
0.0-3999.9 (standard,
position proportional
(closed control)) 2
8.D. PID8
Derivative time
0.0-3999.9
8.OL-H: PID8
MV upper limit
MV lower limit
0.1-105.0
8.OL-L: PID8
MV lower limit
-5.0-MV lower limit
MV upper limit-0.1
8.AUT: PID8
Automatic selection range
upper limit-10% to 110%
(temperature) of sensor
setting range 3
1 Position proportional type: 0.01-999.99
2 Position proportional (floating control) type: 0.1-3999.9
3 Analog type: -10% to 110% of scaling display range, with
a maximum of-19999 to 99999
SI1.1: Straight-line
approximation 1 Input 1
-1.999-9.999
SI2.1: Straight-line
approximation 1 Input 2
-1.999-9.999
SO1.1: Straight-line
approximation 1 Output 1
-1.999-9.999
SO2.1: Straight-line
approximation 1 Output 2
-1.999-9.999
SI1.2: Straight-line
approximation 2 Input 1
-1.999-9.999
SI2.2: Straight-line
approximation 2 Input 2
-1.999-9.999
SO1.2: Straight-line
approximation 2 Output 1
-1.999-9.999
SO2.2: Straight-line
approximation 2 Output 2
-1.999-9.999
FIO1.1: Broken-line
approximation 1 Input 1
-1.999-9.999
FI20.1: Broken-line
approximation 1
Input 20
-1.999-9.999
FO01.1: Broken-line
approximation 1 Output 1
-1.999-9.999
FO20.1: Broken-line
approximation 1
Output 20
-1.999-9.999