50
Safety Device Function Blocks Section 3-5
Error Handling and Error Resetting
Timing Chart When Set to Dual Channel Equivalent
3-5-5 Muting
Basic Function Temporarily disabled the detection operation of a Safety Light Curtain when a
muting sensor is detecting something.
Diagram
General Description The Muting function block provides both muting and override functions.
Muting When detection is muted, safety functions are temporarily disabled so that
workpieces, pallets, or other objects can be passed through the detection
zone of the Safety Light Curtain. With the Muting function block, the input sig-
nal to the Safety Light Curtain will be temporarily disabled when the muting
start conditions are satisfied, and Output Enable will remain ON until the mut-
ing end conditions are satisfied even if the Safety Light Curtain is interrupted.
Error Behavior for error detection Resetting the error
condition Output
Enable
Fault
Present
Error output condition
Discrepancy
error
OFF
(safety
state)
ON Discrepancy
Error output:
ON
Remove the cause of the error
and then do the following:
1. Make the inputs inactive and
then active again.
2. Or change the operating mode
to IDLE Mode and then back to
RUN Mode.
IDLE to RUN
Discre
p
anc
y
time
Input1
(NC)
Output
Enable
Discrepancy
Error
Fault Present
Input2
(NC)
Default Maximum Number of I/O

Other manuals for Omron G9SP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron G9SP Series and is the answer not in the manual?

Omron G9SP Series Specifications

General IconGeneral
TypeSafety Controller
Programming SoftwareSysmac Studio
Supply Voltage24 VDC
Input Voltage24 VDC
Operating Temperature-10 to 55°C
Protection RatingIP20
Number of Safety Outputs4
Safety CategoryCategory 4
Communication InterfacesEthernet/IP
ProgrammingFunction block programming
Vibration Resistance10 to 55 Hz
WeightVaries depending on model

Related product manuals