11 - 29
11 EtherCAT Coupler Unit Functions
NX-series EtherCAT Coupler Unit User’s Manual (W519)
11-9 Resetting Errors
11
11-9-3 Procedure to Reset Errors
1 Connect the computer on which the Sysmac Studio is installed to the peripheral USB port on the
NJ-series CPU Unit or EtherCAT Coupler Unit and go online.
2 Select Troubleshooting from the Tools Menu while online.You can also click the Trouble-
shooting Button in the toolbar.
The following Troubleshooting Dialog Box is displayed.
The current Controller errors are displayed on the Controller Errors Tab Page. (Observations
and information are not displayed.)
3 Click the Reset All Button.
The errors are reset. Any errors for which the causes remain are displayed again.
Resetting the Errors in All Units in the EtherCAT Slave Terminal at
the Same Time