11.10 n: SPECIAL
462 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
n8-79
(05FE)
Pull-In
Curr@Deceleration
Sets, the pull-in current allowed to flow during deceleration as a percentage of the
motor rated current.
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Ac/Dec Pull-In Current].
0%
(0 - 200%)
803
n8-84
(02D3)
Expert
Polarity Det Current
Sets the current that the drive uses to estimate the initial motor magnetic pole as a
percentage where E5-03 [PM Mot Rated Current (FLA)] = 100%.
100%
(0 - 150%)
803
n8-94
(012D)
Expert
FluxPos Est.Method
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not
necessary to change this setting.
1 : Softstarter
2 : Speed Feedback
Determined by d5-01
(1, 2)
803
n8-95
(012E)
Expert
FluxPos Est.Filter Time
Sets the time constant of the filter used for the recognition criteria value for speed and
load changes. Usually it is not necessary to change this setting.
30 ms
(0 - 100 ms)
803