EasyManua.ls Logo

Omron R88M-K - Page 156

Omron R88M-K
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Specifications
3-16
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
z Terminal Block Specifications, Top Terminal Block (TB1)
z Terminal Block Specifications, Bottom Terminal Block (TB2)
Precautions for Correct UsePrecautions for Correct Use
Tighten the terminal block screws to the torque of 1.5 N·m (M5) or 2.5 N·m (M6).
If the torque for terminal block screws exceeds 2.0 N·m (M5) or 3.0 N·m (M6), the terminal
block may be damaged.
Tighten the fixing screw of the terminal block cover to the torque of 0.4 N·m (M5).
Tighten the ground screw to a torque of 2.4 to 2.6 N·m (M6).
Do not connect any External Regeneration Resistors between B1 and NC.
R88D-KN150F-ECT
Symbol Name Function
24 V Control circuit power
supply input
24 VDC ±15%
0 V
DB1 Dynamic Brake Resistor
control terminals
These terminals are used to control the MC for externally connected
dynamic brake resistance. The output contact specifications are 1 A max. at
300 VAC/100 VDC max.
Connect them if required.
DB2
Symbol Name Function
L1 Main circuit power
supply input
R88D-KNF-ECT (15 kW):
3-phase 380 to 480 VAC (323 to 528 VAC) 50/60 Hz
L2
L3
B1 External Regeneration
Resistor connection
terminals
Connect an External Regeneration Resistor between B1 and B2.
B2
NC Do not connect.
U Motor connection
terminals
Red These are the output terminals to the Servomotor.
Be sure to wire them correctly.
VWhite
WBlue
Green/
Yellow
Frame ground This is the ground terminal. Ground to 10 or less.