3-101
3 Specifications
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
3-5 Cable and Connector Specifications
3
3-5-8 Control Cable Specifications
z XW2B-20G5
Note The pitch of terminals is 8.5 mm.
Precautions for Correct UsePrecautions for Correct Use
When using crimp terminals, use crimp terminals with the following dimensions.
When connecting wires and crimp terminals to a terminal block, tighten them to a tightening
torque of 0.59 N·m.
Applicable crimp terminals Applicable wires
Round terminals 1.25 to 3
AWG22 to 16 (0.30 to 1.25 mm
2
)
2 to 3.5
AWG16 to 14 (1.25 to 2.0 mm
2
)
Fork terminals 1.25Y to 3
AWG22 to 16 (0.30 to 1.25 mm
2
)
2 to 3.5
AWG16 to 14 (1.25 to 2.0 mm
2
)
2
1
1
2
20
19
19
20
(45.3)
43.5
29.5
7
8.5 7.3
3.5
7
3.5112.5
15.5
45
2-
Ø
3.5
20.5
Dimensions
Flat cable connector
(MIL type plug)
Terminal block
Ø3.7mm
3.7mm
Round terminal Fork terminal
6.8mm max. 6.8mm max.