4 System Design
4-36
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
Ground the motor's frame to the machine ground when the motor is on a movable shaft.
Use a ground plate for the frame ground for each unit, as shown in the above diagrams, and ground to a
single point.
Use ground lines with a minimum thickness of 3.5 mm
2
, and arrange the wiring so that the ground lines
are as short as possible.
A no-fuse breaker, surge absorber, and noise filter should be positioned near the input terminal block
(ground plate), and I/O lines should be separated and wired at the shortest distance.
z Unit Details
*1 A specified combination of Servo Drive and Servomotor must be used.
Symbol Name Manufacturer Model Comment
SG Surge absorber Okaya Electric
Industries Co., Ltd.
R
·A·V-781BXZ-4
3-phase 200 VAC
NF Noise filter Okaya Electric
Industries Co., Ltd.
SUP-EK5-ER-6 Single-phase 100/200 VAC (5 A)
3SUP-HU10-ER-6 3-phase 200 VAC (10 A)
3SUP-HU30-ER-6 3-phase 200 VAC (30 A)
3SUP-HL50-ER-6B 3-phase 200 VAC (50 A)
SD Servo Drive OMRON *1
SM Servomotor OMRON *1
FC1 Clamp core TDK ZCAT3035-1330
FC2 Clamp core
Konno Kogyosho
RJ8035
FC3 Clamp core NEC TOKIN
Corporation
ESD-SR-250
FC4 Clamp core MICROMETALS T400-61D
R88D-KN75H-ECT/-KN150H-ECT
TDK ZCAT3035-1330 Except for the above
TB Switch box −−