5-17
5 EtherCAT Communications
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
5-8 Sysmac Device Features
5
z SII Data Check
The Slave Information Interface (SII) is an interface area in the nonvolatile memory of an EtherCAT
slave that stores the configuration information specific to that EtherCAT slave.
Sysmac Device EtherCAT slaves check the SII information from the slave side.
If one of these slaves finds that SII information with which it cannot operate was written, it generates an
SII Check Error (Error No. 88.3).If this error persists even after turning OFF and then ON the power
again, contact your OMRON sales representative.
Precautions for Correct UsePrecautions for Correct Use
Do not use third-party or any other configuration tools to edit the SII information.