Appendices
A-48
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
The Synchronization Type indicates the synchronization mode of Sync Manager 3.
0002 hex: DC mode 0
The Cycle time indicates the sync 0 event cycle in nanoseconds.
The Synchronization Types supported indicates the types of synchronization supported.
0004 hex: DC mode 0
The Delay Time is not supported. It reads as 0000 0000 hex.
The Sync Error is 1 when there is a synchronization error.
1C33 hex
Sync Manager3 Synchronization
Sub-index 00 hex Number of Synchronization Parameters
Range Unit Default 20 hex Attribute
Size 1 byte (U8) Access RO PDO map Not possible
Sub-index 01 hex Synchronization Type
Range Unit Default 0002 hex Attribute A
Size 2 bytes (U16) Access RO PDO map Not possible
Sub-index 02 hex Cycle Time
Range Unit ns Default 0000 0000 hex Attribute
Size 4 bytes (U32) Access RO PDO map Not possible
Sub-index 04 hex Synchronization Types supported
Range Unit Default 0004 hex Attribute
Size 2 bytes (U16) Access RO PDO map Not possible
Sub-index 05 hex Minimum Cycle Time
Range Unit ns Default 0000 4268 hex Attribute
Size 4 bytes (U32) Access RO PDO map Not possible
Sub-index 06 hex Calc and Copy Time
Range Unit ns Default 0006 06F8 hex Attribute
Size 4 bytes (U32) Access RO PDO map Not possible
Sub-index 09 hex Delay Time
Range Unit Default 0000 0000 hex Attribute
Size 4 bytes (U32) Access RO PDO map Not possible
Sub-index 20 hex Sync Error
Range Unit Default 0 Attribute
Size 1 bit (BOOL) Access RO PDO map Not possible