4-8
Key sequence Indicator Display
example
Explanation
Displays the parameter number.
Use the Increment or Decrement Key until n32
is displayed.
Press the Enter Key. The data of n32 will be
displayed.
Use the Increment or Decrement Key to set
the rated motor current. The display will flash.
Press the Enter Key so that the set value will
be entered and the data display will be lit.
In approximately
1 s.
The parameter number will be displayed.
5 No-load Operation
•Start
the no-load motor (i.e., not connected to the mechanical system) using the Digital
Operator.
Note
Before operating the Digital Operator
, check that the FREQ adjuster is set to MIN.
Forward/Reverse Rotation with the Digital Operator
Key
sequence
Indicator Display
example
Explanation
Monitors the frequency reference.
Press the RUN Key. The RUN Indicator will be lit.
Turn the FREQ adjuster clockwise slowly.
The monitored frequency reference will be
displayed.
The motor will start rotating in the forward direction
according to the frequency reference.
Press the MODE Key to turn on the F/R indicator.
“For” will be displayed.
Use the Increment or Decrement Key to change the
direction of motor rotation. The direction of motor
rotation selected will be enabled when the display is
changed after the Key is pressed.
Test Run Chapter
4