124
The transfer data is entered in DM words 0010 to 0018. The data and posi-
tioning actions are shown below.
0
#2
(bank end)
#0
(continuous)
#1
9000
Speed #4
DM 1085
DM 1084
Speed #3
START
CCW
Stop
1000
15000
CW
Stop
START
DM 0010 3 0 0 2
DM 0011 9 0 0 0
DM 0012 0 0 0 0
DM 0013 4 0 0 0
DM 0014 5 0 0 0
DM 0015 0 0 0 1
DM 0016 3 0 0 3
DM 0017 1 0 0 0
DM 0018 0 0 0 0