EasyManuals Logo

Omron VARISPEED L7 User Manual

Omron VARISPEED L7
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
5-20
5
Field Forcing: d6
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
d6-03
Field forc-
ing function
selection
Enables or disables field forcing func-
tion.
0:Disabled
1:Enabled
0 or 1 0 No - A A - 2A2H 6-38
Field Force
Sel
d6-06
Field forc-
ing function
Limit
Sets the upper limit for the excitation
current applied by the field forcing
function.
A setting of 100% is equal to the
motor no-load current.
Field forcing is active during all types
of operation except DC Injection.
100 to
400
400% No - A A - 2A5H 6-38
FieldForce
Limit