5-33
5
îš„ Multi-function Contact Outputs: H2
Multi-function Contact Output Functions
88 High Speed Limit Switch (Down) Yes Yes Yes Yes 6-28
89 PG direction change over (0: Clockwise, 1: Counterclockwise) No No Yes No 6-54
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
V/f
with
PG
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
H2-01
Terminal
M1-M2
function
selection
Multi-function contact
output 1
0 to 47 40 No A A A A A 40BH 6-56
Term
M1-M2 Sel
H2-02
Terminal
M3-M4
function
selection
Multi-function contact
output 2
0 to 47 41 No A A A A A 40CH 6-56
Term
M3-M4 Sel
H2-03
Terminal
M5-M6
function
selection
Multi-function contact
output 3
0 to 47 6 No A A A A A 40DH 6-56
Term
M5-M6 Sel
Setting
Value
Function
Control Methods
Page
V/f
Open
loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
0 During run 1 (ON: run command is ON or voltage is being output) Yes Yes Yes Yes 6-56
1 Zero-speed Yes Yes Yes Yes 6-56
2
f
ref
/f
out
agree 1 (detection width L4-02 is used.)
Yes Yes Yes Yes 6-26
3
f
ref
/f
set
agree 1 (ON: Output frequency = ±L4-01, with detection width L4-02 used and dur-
ing frequency agree)
Yes Yes Yes Yes 6-26
4
Frequency detection 1 (ON: +L4-01 ≥ output frequency ≥ -L4-01, with detection width L4-
02 used)
Yes Yes Yes Yes 6-26
5
Frequency detection 2 (ON: Output frequency ≥ +L4-01 or output frequency ≤ -L4-01, with
detection width L4-02 used)
Yes Yes Yes Yes 6-26
6 Inverter operation ready; READY: After initialization or no faults Yes Yes Yes Yes 6-57
7 During DC bus undervoltage (UV) detection Yes Yes Yes Yes 6-57
8 During baseblock (ON: during baseblock) Yes Yes Yes Yes 6-57
9 Frequency reference source selection (ON: Frequency reference from Operator) Yes Yes Yes Yes 6-57
A Run command source selection status (ON: Run command from Operator) Yes Yes Yes Yes 6-57
B Car stuck/undertorque detection 1 NO (NO contact, ON: Overtorque/undertorque detection) Yes Yes Yes Yes 6-40
E
Fault (ON: Digital Operator/Monitor communications error or fault other than CPF00 and
CPF01 has occurred.)
Yes Yes Yes Yes 6-57
F Not used. (Set when the terminal is not used.) Yes Yes Yes Yes -
10 Minor fault (ON: Alarm displayed) Yes Yes Yes Yes 6-57
11 Fault reset command active Yes Yes Yes Yes 6-57
Setting
Value
Function
Control Methods
Page
V/f
Open
Loop
Vec-
tor
Closed
Loop
Vector
Closed
Loop
Vector
(PM)