5-56
5
U1-11
Output terminal
status
Shows output ON/OFF status.
(Cannot be output.) - A A A A 4AH
Output Term Sts
U1-12
Operation status
Inverter operating status.
(Cannot be output.) - A A A A 4BH
Int Ctl Sts 1
U1-13
Cumulative
operation time
Monitors the total operating
time of the Inverter.
The initial value and the operat-
ing time/power ON time selec-
tion can be set in o2-07 and o2-
08.
(Cannot be output.)
1
hr.
AA A A 4CH
Elapsed Time
U1-14
Software No.
(flash memory)
(Manufacturer’s ID number) (Cannot be output.) - A A A A 4DH
FLASH ID
U1-15
Terminal A1
input level
Monitors the input level of ana-
log input A1. A value of 100%
corresponds to 10V input.
10 V: 100%
(0 to ± 10 V possible)
0.1% A A A A 4EH
Term A1 Level
U1-16
*1
AI-14B channel
2 input level
Monitors the input level of ana-
log input 2 on a AI-14B option
board. A value of 100% is equal
to 10V input.
10 V: 100%
(0 to ± 10 V possible)
0.1% A A A A 4FH
AI-14 Ch2
InpLvl
U1-17
*1
AI-14B channel
3 input level
Monitors the input level of ana-
log input 3 on a AI-14B option
board. A value of 100% is equal
to 10V input.
10 V: 100%
(0 to ± 10 V possible)
0.1% A A A A 50H
AI-14 Ch3
InpLvl
U1-18
Motor second-
ary current (Iq)
Monitors the calculated value
of the motor secondary current.
The motor rated current corre-
sponds to 100%.
10 V:Motor rated current)
(0 to ±10 V output)
0.1% A A A A 51H
Mot SEC Cur-
rent
U1-19
Motor excita-
tion current (Id)
Monitors the calculated value
of the motor excitation current.
The motor rated current corre-
sponds to 100%.
10 V:Motor rated current)
(0 to ±10 V output)
0.1% - A A A 52H
Mot EXC cur-
rent
Param-
eter
Num-
ber
Name
Description
Output Signal Level During
Multi-Function Analog Output
Min.
Unit
Control Methods
MEMO-
BUS
Register
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
1: Multi-function
contact output 1
(M1-M2) is ON
1: Multi-function
contact output 2
(M3-M4) is ON
1: Multi-function
contact output 3
(M5-M6) is ON
Not used
(Always 0).
1: Error output
(MA/MB-MC) is
ON
Run
1: Zero speed
1: Reverse
1: Reset signal
input
1: Speed agree
1: Inverter ready
1: Minor fault
1: Major fault