1. In the SMTP Settings field in the Alerts & Logging > SMTP &SMS menu select SMS Gateway. An
SMS via Email Gateway field appears
2. Enter the IP address of the outgoing mail Server SMS gateway
3. Select a Secure Connection (if applicable) and specify the SMTP port (if other than the default
port 25)
4. Enter a Sender email address as the from address in all email notifications sent from this console
server. Some SMS gateway service providers only forward email to SMS when the email has been
received from authorized senders.
5. Enter a Username and Password as some SMS gateway service providers use SMTP servers
which require authentication
6. Enter the Subject Line for the email. The email subject will contain a truncated version of the alert
notification message, contained in full in the body of the email. Some SMS gateway service
providers require blank subjects or authentication headers included in the subject line
7. Click Apply Settings to activate SMS-SMTP connection.
SMS via Cellular Modem
To use an attached or internal cellular modem for SMS, an administrator must enable SMS:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS
Weight and Dimensions IconWeight and Dimensions
Depth120 mm
Width130 mm
Height35 mm
Weight6000 g