Environmental Specifications
For the Acme Packet 6300/6350 to function properly, Acme Packet recommends that
you follow the environmental guidelines in the following table.
Table 7-7 Acme Packet 6300/6350 Environmental Specifications
Specification Description
Temperature The Acme Packet 6300/6350 System is required to operate
within the temperature range of:
* +0° C to +40° C, 32° F to 104° F (operating)
* -20° C to +65° C, -4° F to 149° F (storage)
Relative Humidity Operating conditions of 10% to 85% humidity under non-
condensing operating conditions
Maximum Altitude The Acme Packet 6300/6350 System is required to operate
below the maximum altitude of 10,000 feet.
Air Flow 300 CFM
Power Dissipation 250W typical 350W maximum (base system with 2x10 G NIU)
Additional 150W for second 2 x 10GbE NIU
Additional 275W for each fully populated transcode carrier card
Connector Specifications
Refer to the following table for information about the connector specifications for the
Acme Packet 6300/6350.
Table 7-8 Acme Packet 6300/6350
Specification Description
RJ45/Management Ethernet
Ports
The 3 x 8-pin RJ45 10/100/1000BaseT Ethernet ports are
compliant with IEEE's 802.3, 802.3u, and 802.3ab.
RJ45/Alarm Contact Port Any alarms generated by the system are accessible via the
8-pin RJ45 alarm contact port.
RS232/Serial Port The RS232 serial port uses an 8-pin RJ45 connector that
supports RS232-C protocol.
10GbE Port(s) The 10GbE fiber optic connection ports use duplex LC
connectors.
IEC Connector Ports The IEC connector ports accept a 3-lead IEC-320 connector for
AC power installations.
Optical Transceiver Interface Module Specification
Refer to the following table for information about the optical specifications of the
10GbE SFP+ optical transceivers for the Acme Packet 6300/6350.
Chapter 7
Environmental Specifications
7-3