Configuring Policy Settings
These topics describe managing configuration policies using Oracle ILOM.
“Specify Cooldown Mode” on page 57
“Restore the Host Power State at Restart” on page 58
“Specify the Host Power State at Restart” on page 59
“Disable or Reenable the Host Power-On Delay” on page 59
“Specify Parallel Boot of the SP and Host” on page 60
“Specify Host Virtual Keyswitch Behavior” on page 60
“Reset the Values in the SP to Default Values” on page 61
Related Information
“Configuring Boot and Restart Behavior” on page 43
Specify Cooldown Mode
Some servers support the host cooldown mode, but not all. Setting the HOST_COOLDOWN property
to enabled causes the server to enter cooldown mode while the host is powering off. The
cooldown mode directs Oracle ILOM to monitor certain components to ensure that they are
below a minimum temperature, so as not to cause harm to the user if internal components are
accessed.
Once the components are below the threshold temperature, power is removed from the server,
which enables the cover interlock switch to release. If the monitored temperatures take longer
than four minutes to reach the threshold, the host turns off.
At the Oracle ILOM prompt, type:
-> set /SP/policy HOST_COOLDOWN=value
where value can be:
Configuring Policy Settings 57

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Netra SPARC S7-2 Series and is the answer not in the manual?

Oracle Netra SPARC S7-2 Series Specifications

General IconGeneral
BrandOracle
ModelNetra SPARC S7-2 Series
CategoryServer
LanguageEnglish

Related product manuals