Configure SP In-band (Sideband) Access
2.
Log in to Oracle ILOM.
See “Log In to Oracle ILOM” on page 19.
3.
If you logged in using the serial port, assign a static IP address.
For instructions, refer to the information about assigning a static IP address in the installation
guide for the server.
4.
View the current network settings.
-> show /SP/network
For example, in the output, you might find these properties:
managementport = MGMT
...
pendingmanagementport = MGMT
...
MGMT indicates the NET MGT port.
5.
Configure a network port for the SP.
Type a port value of NET0, NET1, NET2, or NET3.
-> set /SP/network pendingmanagementport=port
6.
Configure ipaddress and ipconfig as needed.
Refer to the section about assign an IP address in the installation guide the server.
7.
Commit the network configuration changes.
->set /SP/network commitpending=true
8.
Verify the change.
-> show /SP/network
For example, in the output, you might find these new properties:
managementport = NET0
...
pendingmanagementport = NET0
Related Information
“Oracle ILOM In-band (Sideband) Management” on page 66
“SP Network Address Options” on page 63
Configuring SP and Host Network Addresses 67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Netra SPARC S7-2 Series and is the answer not in the manual?

Oracle Netra SPARC S7-2 Series Specifications

General IconGeneral
BrandOracle
ModelNetra SPARC S7-2 Series
CategoryServer
LanguageEnglish

Related product manuals