Position to Element
Julyl 2017 Command Set 179
Position to Element
The Position to Element command (2Bh) is supported only for compatibility with
existing applications. It causes the hand to be positioned to the specified destination
element address.
TABLE 4-99 Position to Element Command
Byte
Bit
76543210
0 Operation Code (2Bh)
1 Ignored Reserved (00h)
2
to
3
(MSB)
Transport Element Address
(LSB)
4
to
5
(MSB)
Destination Element Address
(LSB)
6 Reserved (00h)
7 Reserved (00h)
8 Reserved (00h) Invert (0)
9 Control Byte (00h)
Position to Element Command Definitions:
Transport Element
Address
This field defines the hand element to use and should contain the element address
of the hand or 00h (0d). A value of 00h (0d) indicates use of the default hand.
Destination Element
Address
This field defines the address of the element where the hand is to be positioned.
Invert The library does not support this function and requires a value of 0.

Table of Contents

Other manuals for Oracle storagetek sl150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle storagetek sl150 and is the answer not in the manual?

Oracle storagetek sl150 Specifications

General IconGeneral
BrandOracle
Modelstoragetek sl150
CategoryStorage
LanguageEnglish

Related product manuals