Initialize Element Status With Range
Julyl 2017 Command Set 31
Initialize Element Status With Range
The Initialize Element Status With Range command (37h and E7h) is a request from
the host to perform an inventory of a portion of the cartridge tapes within the library.
The library accepts this command for compatibility but does not perform any action.
When the library powers-on it performs an audit of and maintains the inventory
during operations. The library also performs an audit after someone has opened and
closed the front door.
An initiator can obtain inventory information for the library by using the Read
Element Status command.
TABLE 4-7 Initialize Element Status With Range Command
Byte
Bit
76543210
0 Operation Code (37h/E7h)
1 Ignored Reserved (00h) Fast Range
2
to
3
(MSB)
Element Address
(LSB)
4
to
5
(MSB)
Reserved (00h)
(LSB)
6
to
7
(MSB)
Number of Elements
(LSB)
8 Reserved (00h)
9 Control Byte (00h)
Initialize Element Status with Range Definitions:
Fast Ignore this field.
Range Ignore this field.
Element Address Ignore this field.
Number of Elements Ignore this field.

Table of Contents

Other manuals for Oracle storagetek sl150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle storagetek sl150 and is the answer not in the manual?

Oracle storagetek sl150 Specifications

General IconGeneral
BrandOracle
Modelstoragetek sl150
CategoryStorage
LanguageEnglish

Related product manuals