EasyManua.ls Logo

Oval ALTImass CA004 - 11.4 Regarding FISCO System of FOUNDATION fieldbus and PROFIBUS

Oval ALTImass CA004
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
L-737-3-E
89
11.3 Inductance and Internal Resistance of Sensor Coil
Do not perform a repair involving the explosionproof construction. If servicing is necessary, contact your
nearest OVAL sales office or sales representative.
Sensor model
Drive circuit Circuits other than drive circuit
Drive coil
Drive
Resistance
(Ω)
Pickoff coil
Pickoff
resistance
(Ω)
Li max
(mH)
R min
(Ω)
Li max
(mH)
R min
(Ω)
CA0041XX
33.7 377.0
3.6 69.0
Fig.11.3
11.4 Regarding FISCO System of FOUNDATION fieldbus and PROFIBUS
Bus Line Connection Diagram
If the 16th digit of product code is2 : FOUNDATION fieldbus (FF), Communication Specificationor
3 : PROFIBUS, Communication Specification, the transmitter is compatible with Intrinsic Safety
(IEC60079-11 Annex G).
Below are the allowable parameters of ALTImass transmitter:
Ui17.5V, Ii380mA, Pi=5.32W , Cinegligible low, Li10μH
Transmitter label to show the FF and PROFIBUS specifications
INTEGRAL MODEL
SEPARATE MODEL
POWER
POWER
TRANSMITTER
Ex d
ib
Ex d ib
Ex i
SENSOR
Ex ib
T
BUSLINE(FISCO)