SECTION 5 REMOTE OPERATION
81
5.3.1 STEADY-STATE OUTPUT PARAMETERS
FORM,<n> sets Output Power Form of selected program.
n = <1>Single Φ, <2>Split Φ, or <3>Three Φ
COUPLing,<s> sets Output coupling of selected program.
s = <DIRECT> or <XFMR>
XFMRRATIO,<n.nn> sets Output XFMR ratio (n.nn:1) of selected program.
n.nn = <0.05> to <5.00>
FREQuency,<n> sets Output Frequency of selected program.
n = <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz.
VOLTage,<n> sets Output VOLTAGE ΦA, ΦB, ΦC of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage1,<n> sets Output VOLTAGE ΦA of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage2,<n> sets Output VOLTAGE ΦB of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VOLTage3,<n> sets Output VOLTAGE ΦC of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
CURRent:LIMit, <n> sets Output Current Limit of selected program.
n = <0> to <AMPS meter range> Amps
PHASe2,<n> sets Output Φ angle B of selected program.
n = <0> to <359> degrees
PHASe3,<n> sets Output Φ angle C of selected program.
n = <0> to <359> degrees
WAVEFORM,<n> sets Output Waveform ΦA, ΦB, ΦC of selected program.
n = <1> to <16>
WAVEFORM1,<n> sets Output Waveform ΦA of selected program.
n = <1> to <16>
WAVEFORM2,<n> sets Output Waveform ΦB of selected program.
n = <1> to <16>
WAVEFORM3,<n> sets Output Waveform ΦC of selected program.
n = <1> to <16>
EVENTS <n> sets number of times to repeat the transient portion of the selected program
when the Transient is executed.
n = 0-65535. A value of 0 specifies continuous repetition.