SECTION 5 REMOTE OPERATION
83
5.3.3 PROGRAM MEMORY CONTROL
:PROGram:[SELected:]DELete Command
: (No query) deletes selected program.
:PROGram:DELete:ALL Command
: (No query) deletes all programs, waveforms, calibration
data and setup values. Performs device RESET, loads Program #1
with *RST default values, executes MANUAL MODE with *RST values.
Waveforms (1-16) are re-loaded from ROM.
NOTE
: Calibration values are deleted.
:PROGram:COPY <dest> Command
: (No query) copies the selected program (previously
specified by :PROG:NAME <nn>) to <dest>.
<dest> = 1 thru 99
NOTE
: that the destination program cannot be currently executing.
:PROGram:CATalog? <list> Query
: returns a comma separated list of NR1 values representing
stored programs (e.g. 1,2,7…). If the MANUAL MODE program exists,
list includes 0. If no programs are stored, query returns -1.
5.4 SIGNAL CONTROL
5.4.1 OUTPUT PARAMETERS
:PROGram:EXECute Command
: executes selected Program steady-state values. Selected
program is specified by previous PROGram:NAME <nn> command.
Query
: returns the number of the currently executing program. If no
program is executing, query returns -1.
:PROGram:EXECute:TRANS Command
: (No query) executes pre-processed Transient portion of
selected Program. Pre-processing is performed by executing a
Program. Transient terminates upon receipt of any data byte (DAB)
from the IEEE-488 Bus, Device Clear, or when the LAST segment of
the last EVENT is executed. Steady-state values are then restored.
Follow this command (in the same Program Message) with *OPC to
detect termination of the Transient event. An SRQ occurs when the
Transient is complete (if ESB bit is set in SRE and OPC bit is set in
ESE). *OPC? may be used in the same manner.
*TRG Same as :PROGram:EXECute:TRANS
:[SOURce:]VOLTage <n> sets Output VOLTAGE amplitude of all available Phases.
n = <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage1 <n> sets Output VOLTAGE ΦA.
n = <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage2 <n> sets Output VOLTAGE ΦB.
n = <0> to <150, or 150 x XFMRRATIO> Volts
:[SOURce:]VOLTage3 <n> sets Output VOLTAGE ΦC.
n = <0> to <150, or 150 x XFMRRATIO> Volts