EasyManuals Logo

Pacific Power Source UPC-3 User Manual

Default Icon
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
SECTION 5 REMOTE OPERATION
82
5.3.2 TRANSIENT SEGMENT PARAMETERS
SEGment,<n> selects transient segment “n” of the presently selected Program to be
edited.
n = <1> to <100>
FSEG,<n> sets objective Frequency of selected segment.
n = <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz.
VSEG,<n> sets objective voltage ΦA, ΦB, ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG1,<n> sets objective voltage ΦA of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG2,<n> sets objective voltage ΦB of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG3,<n> sets objective voltage ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
WFSEG,<n> sets Waveform ΦA, ΦB, ΦC of selected segment.
n = <1> to <22>
WFSEG1,<n> sets Waveform ΦA of selected segment.
n = <1> to <22>
WFSEG2,<n> sets Waveform ΦB of selected segment.
n = <1> to <22>
WFSEG3,<n> sets Waveform ΦC of selected segment.
n = <1> to <22>
TSEG,<n> sets execution time (to reach objective Voltage and Frequency) of
selected segment.
n = <0> or <.0002> to <300> seconds. Setting n to <0> selects cycle-
based transient operation, i.e., each segment time is equal to the
period of 1 cycle (1/FREQ)
LAST sets selected segment to be the last segment of selected transient.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pacific Power Source UPC-3 and is the answer not in the manual?

Pacific Power Source UPC-3 Specifications

General IconGeneral
BrandPacific Power Source
ModelUPC-3
CategoryController
LanguageEnglish

Related product manuals