5.3.2 TRANSIENT SEGMENT PARAMETERS
SEGment,<n> selects transient segment “n” of the presently selected Program to be
edited.
n = <1> to <100>
FSEG,<n> sets objective Frequency of selected segment.
n = <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz.
VSEG,<n> sets objective voltage ΦA, ΦB, ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG1,<n> sets objective voltage ΦA of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG2,<n> sets objective voltage ΦB of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
VSEG3,<n> sets objective voltage ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
WFSEG,<n> sets Waveform ΦA, ΦB, ΦC of selected segment.
n = <1> to <22>
WFSEG1,<n> sets Waveform ΦA of selected segment.
n = <1> to <22>
WFSEG2,<n> sets Waveform ΦB of selected segment.
n = <1> to <22>
WFSEG3,<n> sets Waveform ΦC of selected segment.
n = <1> to <22>
TSEG,<n> sets execution time (to reach objective Voltage and Frequency) of
selected segment.
n = <0> or <.0002> to <300> seconds. Setting n to <0> selects cycle-
based transient operation, i.e., each segment time is equal to the
period of 1 cycle (1/FREQ)
LAST sets selected segment to be the last segment of selected transient.