SECTION 2 SPECIFICATIONS
13
2.2.4 KILOWATT METER SPECIFICATIONS
True kilowatt power metering is provided using the voltmeter and ammeter inputs. Display range and
resolution is XXX.XXX kW. The Remote interface may provide 3 digits of precision (digits to the right of
the decimal point).
Accuracy is ± 1% of full scale over the full range of ambient conditions.
2.2.5 POWER FACTOR METER SPECIFICATIONS
Power factor is displayed as the ratio: kW / kVA. Display range and resolution is X.XXX. The Remote
interface may provide 3 digits of precision (digits to the right of the decimal point).
Accuracy is ± 1% of full scale over the full range of ambient conditions.
2.2.6 FREQUENCY DISPLAY SPECIFICATIONS
The programmed frequency is displayed as an indicator only. Internally, there are 3 Frequency Spans,
each with a different resolution (see 2.1.1). The UPC typically performs auto-ranging based on the
selected frequency but the Frequency Span can be specified (see 4.6.3.2).
Range: 15.00 – 1200 Hz..
10.00 to 99.99 Hz. 0.01 Hz.
100.0 to 999.9 Hz. 0.1 Hz. Resolution
1000 to 1200 Hz. 1 Hz.
Accuracy (over the full range of ambient conditions) ± 0.01% of full scale
2.2.7 WAVEFORM ANALYSIS
(Option: Harmonic Analysis and Synthesis)
The UPC WAVEFORM ANALYSIS function is an optional feature which derives harmonic content values
for any of the output voltage or current waveforms. Harmonics are displayed in tabular form on the front
panel LCD display or may be queried via the Remote Interface. Also displayed is Total Harmonic
content (THD) and individual sums of even and odd harmonics (EHD & OHD). THD is the RMS of EHD
and OHD. The Harmonic analysis function reports both magnitude and phase angle (relative to 0º of
voltage) of each harmonic for metered voltage and current waveforms.
Fundamental Frequency Range (Fout): 15-1200 Hz.
Harmonic Range: 2nd - 51st Harmonic.
Harmonic Content (Magnitude):
Accuracy: (see NOTE 1) ± 1% of Fundamental
Resolution: 0.1 %
Harmonic Phase Angle (see NOTE 2):
Accuracy: Fout < 100 Hz. 2nd-20th: ± 1º
21st-51st: ± 2º
100 <=Fout<1000 ± 6º
Fout >1000 Hz. ± 8º
Resolution:(0º - 359º)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pacific Power Source UPC-3 and is the answer not in the manual?

Pacific Power Source UPC-3 Specifications

General IconGeneral
BrandPacific Power Source
ModelUPC-3
CategoryController
LanguageEnglish

Related product manuals