(A: Available, N/A: Not available)
Address Name Description
Read-
ing
Writ-
ing
DT90058
Clock/calendar time
setting
For L40/L60
It is used to adjust the time of the built-in
clock/calendar.
When setting the clock/calendar by
program
By setting the highest bit of DT90058 to 1, the
time becomes that written to DT90054 to
DT90057 by F0 (MV) instruction. After the
time is set, DT90058 is cleared to 0. (Cannot
be performed with any instruction other than
F0 (MV) instruction.)
<Example>
Set the time to 12:00:00 on the 5th day when
the X0 turns on.
Note) If the values of DT90054 to DT90057
are changed with the programming tool
software, the time will be set when the new
values are written. Therefore, it is
unnecessary to write to DT90058.
A A
DT90059
Communication error
code
Error code is stored here when a
communication error occurs.
N/A N/A