Top Menu Camera menu Item Factory setting Selection items
SCENE
FILE
USER
FILE
FILES SCENE FILE MODE LOAD LOAD, STORE
FILE NO OFF When [MODE] is set to [LOAD]: OFF/1 to 8
When [MODE] is set to [STORE]: 1 to 8
FILE NAME SCENE1 to
SCENE8
Within 15 characters
(Alphanumeric characters, spaces, ! # % & ' ( )
*
+ , - . / : ; < = > ? [ ] _
~
$ @ |)
LIST SCENE1
SCENE2
SCENE3
EXECUTE --- NO, YES
USER FILE MODE LOAD LOAD, STORE
FILE NO 1 1, 2, 3
FILE NAME USER1 to USER3 Within 15 characters
(Alphanumeric characters, spaces, ! # % & ' ( )
*
+ , - . / : ; < = > ? [ ] _
~
$ @ |)
LIST USER1
USER2
USER3
EXECUTE --- NO, YES
MAINTENANCE FAN SETTING FAN1 HIGH AUTO, LOW, MID, HIGH
FAN2 HIGH AUTO, LOW, MID, HIGH
DATE/TIME PRESENT (Current time displayed)
DATE YY 23 23 to 99
DATE MM 01 01 to 12
DATE DD 01 01 to 31
TIME HH 00 00 to 23
TIME MM 00 00 to 59
TIME SS 00 00 to 59
SET EXECUTE --- NO, YES
RESET --- NO, YES
INITIALIZE MENU INITIALIZE --- NO, YES
ALL DATA INITIALIZE --- NO, YES
VERSION SYSTEM VERSION Shipped version
HOUR METER OPERATION 00000000 (Display only) 8-digit number
FAN1 00000000 (Display only) 8-digit number
FAN2 00000000 (Display only) 8-digit number
HDMI STATUS CONNECT --- ---
FORMAT --- ---
VIDEO SAMPLING --- ---
MONITOR --- ---