or
Test again?
Do another Test?
Yes
(16) Adjust Double Feed Detector
Select a menu of Setting Item by
8
(From Section 9.6)
pushing “ ” or “ ” key.
Set paper on Scanner.
Push STOP/START key once.
Confirm the Test result.
9
Push HOME key once.
(To Section 9.6)
Push STOP/START key once.
No
(17) Adjust Length
(18) Adjust Front V. position
(19) Adjust Front H. position
(20) Adjust Back V. position
(21) Adjust Back H. position
(22) Adjust All position &
(23) Adjust Shading
Automatically
Automatically
Automatically
Automatically
Automatically
Length Automatically
(17)-(22) Set Test chart A.
Note: (17) Front Side
(23) Set Shading paper.
(16) Set Adjustment paper.
(18) Front Side (*Set 2pcs of Test
chart on account of including
adjustment for the function of
"Sensor Delay automatically".
Front Side
(19) Front Side
(20) Back Side
(21) Back Side
(22) Set 6 charts in following order
Front Side
Front Side
Back Side
Back Side
Note: Part number of these charts or
paper are shown on SECTION15.
1
3
5
6
2
Front Side
4