2.9 Connection of Extensions
2.9.1 Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
SLT
Cable Maximum Distance
ø 0.4 mm: 500 m
ø 0.5 mm: 720 m
ø 0.6 mm: 830 m
CAT 5: 720 m
Cable Maximum Distance
ø 0.4 mm: 140 m
ø 0.5 mm: 229 m
ø 0.6 mm: 360 m
CAT 5: 229 m
Cable Maximum Distance
ø 0.4 mm: 698 m
ø 0.5 mm: 1128 m
ø 0.6 mm: 1798 m
CAT 5: 1128 m
Other PT (DPT/APT)
and DSS Console
KX-T7600 Series DPT
PT-interface CS
(Basic/High-density)
Cable Maximum Distance
ø 0.4 mm: 222 m
ø 0.5 mm: 347 m
ø 0.6 mm: 500 m
CAT 5: 347 m
Notice
If the cabling distance exceeds the maximum cabling distance above, satisfactory performance of each
terminal cannot be guaranteed.
The connected terminals will operate over the maximum cabling distance under optimum conditions.
However, the maximum cabling distance of SLTs connected to ports No. 9–24 of the ECSLC24 card
may be shorter than that of SLTs connected to the ESLC16 card.
PT-interface
CS
(Basic/
High-density)
DPT APT
DSS
Console
SLT
DHLC8 Card
ü ü ü ü ü
EMSLC16, ESLC16,
ECSLC24, CSLC16
,
SLC8 Cards
ü