35
[Preparation]
Preparation
In Case of Single Phase, 100V (A and B-frame) In Case of Single Phase, 200V (A and B-frame)
In Case of Single Phase, 200V (C and D-frame)
In Case of 3-Phase, 200V (C and D-frame)
A
B
D
C
AHG
CDE
BIF
CBA
IHG
FED
JL04V-2E20-4PE-B-R
JL04HV-2E22-22PE-B-R
JL04V-2E20-18PE-B-R JL04V-2E24-11PE-B-R
Power supply Single phase, 100V to 115V
+10%
–15%
+10%
–15%
Power supply Single phase, 200V to 240V
+10%
–15%
+10%
–15%
Noise
filter
Main power
supply
Control power
supply
Motor
ALM
15
ALM
L3
L1C
L2C
RB1
MC
NFB
RB3
RB2
U
V
W
L1
CN X2
Surge absorber
External regenerative resistor
COM–
17
DC12 to 24V
(±5%)
Red
White
Black
Green
1
2
3
4
1
2
3
4
Motor
connection
CN X5
CN X1
172167-1
Tyco Electronics AMP
172159-1
Tyco Electronics AMP
L
MC
ALMON OFF
Built-in thermostat of an external
regenerative resistor (light yellow)
MC
Noise
filter
Main power
supply
Control power
supply
Motor
ALM
L3
L1C
L2C
RB1
MC
NFB
RB3
RB2
U
V
W
L1
CN X2
External regenerative resistor
DC12 to 24V
(±5%)
Red
White
Black
Green
1
2
3
4
1
2
3
4
Motor
connection
CN X5
CN X1
172167-1
Tyco Electronics AMP
172159-1
Tyco Electronics AMP
L
MC
ALMON OFF
Use a reactor for
3-phase
Surge absorber
Built-in thermostat of an external
regenerative resistor (light yellow)
MC
15
ALM
COM–
17
PIN No.
Application
PIN No.
Application
External regenerative resistor
<Remarks>
When you use single
phase, connect the main
power between L1 and
L3 terminals.
Motor
L2
L3
L1C
L2C
RB1
MC
NFB
RB3
RB2
U
V
W
L1
1
2
3
4
1
2
3
4
(Remove the short wire when you connect 
the external regenerative resistor.)
172167-1
Tyco Electronics AMP
172159-1
Tyco Electronics AMP
L
<Remarks>
When you use single
phase, connect the main
power between L1 and L3
terminals.
Motor
L2
L3
L1C
L2C
RB1
MC
NFB
RB3
RB2
U
V
W
L1
1
2
3
4
1
2
3
4
(Remove the short wire when you connect
the external regenerative resistor.)
*
172167-1
Tyco Electronics AMP
172159-1
Tyco Electronics AMP
L
A U-phase
V-phase
W-phase
Ground
PIN No.
B
C
D
Application
G
H
A
F
I
B
E
D
C
Brake
Brake
NC
U-phase
V-phase
W-phase
Ground
Ground
NC
A Brake
Brake
NC
U-phase
V-phase
W-phase
Ground
Ground
NC
B
C
D
E
F
G
H
I
<Remark> 
Do not connect anything to NC.
* When you use motor model of
MSMA, MDMA, MFMA, MHMA
and MGMA, use the connections
as the below table shows. 
[Motor portion] 
Connector : by Japan Aviation Electronics Ind.
CN X2
CN X1
ALM
DC12 to 24V
(±5%)
CN X5
CN X2
CN X1
CN X5
ALM
DC12 to 24V
(±5%)
MC
ALMON OFF
MC
ALMON OFF
Use a reactor for
3-phase
Noise
filter
Noise
filter
Main power
supply
Control power
supply
Motor
connection
Main power
supply
Control power
supply
Motor
connection
Power supply Single phase, 200V to 240V
+10%
–15%
+10%
–15%
Power supply 3-phase, 200V to 240V
+10%
–15%
+10%
–15%
Red
White
Black
Green
External regenerative resistor
Red
White
Black
Green
*
Surge absorber
Built-in thermostat of an external
regenerative resistor (light yellow)
MC
Surge absorber
Built-in thermostat of an external
regenerative resistor (light yellow)
MC
15
ALM
COM–
17
15
ALM
COM–
17
Wiring Diagram
Compose the circuit so that the main circuit power will be shut off when an error occurs.

Table of Contents