Command data format
It is the data format used for sending and receiving commands.
r Transmitted data
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
f Example: Transmission of power supply status acquisition command
“00QPW” (CR)
r Received data
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
f Example: The projector is in standby status
“00000” (CR)
r Error response
String Details Termination symbol
Message
"ERR1" Undened control command
(CR)
0x0d
"ERR2" Out of parameter range
"ERR3" Busy state or no-acceptable period
"ERR4" Timeout or no-acceptable period
"ERR5" Wrong data length
Data length 4 bytes 1 byte
Note
f The projector automatically disconnects from the network immediately after sending the command. Such specications are made from the
viewpoint of security, such as prevention of illegal operation of the projector by a malicious third party. To send commands continuously,
make a request for network connection every time and send it. For details, see “Communication ow between the server and the client”
(x page 148).
Communication ow between the server and the client
When sending / receiving commands via LAN, refer to the communication ow shown below.
Server: the projector
Client: the control device such as a computer
Client
Server
First session
Second session
Connection query
Sending key
Send rst command
Respond rst command
Cut off
Connection query
Sending key
Send second command
Respond second command
Cut off
148 - ENGLISH