SC-HM910/SC-HM810
37
12.2.2.AM RF Adjustment
1. Connect the instrument as shown in Fig. 7.
2. Set the unit to AM mode.
3. Set AM-SG to 520 kHz.
4. Receive 520 kHz in the unit.
5. Adjust Z101 (OSC) so that the EVM-AC is maximized.
6. Set AM-SG to 520 kHz.
7. Receive 600 Hz in the unit.
8. Adjust Z101 (ANT) so that the EVM-SG is maximized.
12.3. Alignment Points
12.3.1.Cassette Deck Section
9. Set AM-SG to 520 kHz.
10. Receive 520 kHz in the unit.
11. Adjust Z101 (OSC) so that the EVM-DC value es with
1.1 ± 0.5V.
12.3.2.Adjustment Point