33 Programming Guide
13 = Cold start wireless module (Partition 1 only) 01 to 16 = Output number
17 to 18 = Wireless repeater
19 to 22 = Wireless keypad
99 = Any output number
14 = Bypass programming 01 to 32 = User number
99 = Any user number
15 = User code activated output (Partition 1 only)
16 = Wireless smoke maintenance signal 01 to 32 = Zone number
99 = Any zone number
17 = Delay zone alarm transmission
18 = Zone signal strength weak 1 (Partition 1 only)
19 = Zone signal strength weak 2 (Partition 1 only)
20 = Zone signal strength weak 3 (Partition 1 only)
21 = Zone signal strength weak 4 (Partition 1 only)
22 = Button pressed on remote (see button option “5”) 01 to 32 = Remote control number
99 = Any remote control number
23 = Button pressed on remote (see button option “6”)
24 = Fire Delay started 01 to 32 = Zone number
99 = Any zone number
25 = N/A
26 = Software Access (VDMP3, IP100, NEware, WinLoad) 00 = Non-valid source ID
01 = WinLoad direct
02 = WinLoad through IP module
03 = WinLoad through GSM module
04 = WinLoad through modem
05 = NEware direct
06 = NEware through IP module
07 = NEware through GSM module
08 = NEware through modem
09 = IP100 direct
10 = VDMP3 direct
11 = Voice through GSM module
12 = Remote access
13 = SMS through GSM module
99 = Any software access
27 = Bus module event 00 = A bus module was added
01 = A bus module was removed
02 = 2-way RF Module Communication Failure
03 = 2-way RF Module Communication Restored
28 = StayD pass acknowledged 01 to 32 = Zone number
99 = Any zone number
29 = Arming with user 01 to 32 = User number
99 = Any user number
30 = Special arming 00 = Auto-arming (on time/no movement)
01 = Late to close
02 = No movement arming
03 = Partial arming
04 = Quick arming
05 = Arming through WinLoad
06 = Arming with keyswitch
99 = Any special arming
31 = Disarming with user 01 to 32 = User number
99 = Any user number
32 = Disarming after alarm with user
33 = Alarm cancelled with user
Event Group # Sub-group #