Magellan / Spectra SP 34
34 = Special disarming 00 = Auto-arm cancelled (on time/no movement)
01 = Disarming through WinLoad
02 = Disarming through WinLoad after alarm
03 = Alarm cancelled through WinLoad
04 = Paramedical alarm cancelled
05 = Disarm with keyswitch
06 = Disarm with keyswitch after an alarm
07 = Alarm cancelled with keyswitch
99 = Any special disarming
35 = Zone bypassed 01 to 32 = Zone number
99 = Any zone number
36 = Zone in alarm
37 = Fire alarm
38 = Zone alarm restore
39 = Fire alarm restore
40 = Special alarm 00 = Panic non-medical emergency
01 = Panic medical (this panic alarm is not UL approved)
02 = Panic fire
03 = Recent closing
04 = Global shutdown
05 = Duress alarm
06 = Keypad lockout (Partition 1 only)
99 = Any special alarm event
41 = Zone shutdown 01 to 32 = Zone number
99 = Any zone number
42 = Zone tampered
43 = Zone tamper restore
44 = New trouble
(Partition 1 only except sub-group 07 = both partitions)
00 = N/A
01 = AC failure
02 = Battery failure
03 = Auxiliary current overload
04 = Bell current overload
05 = Bell disconnected
06 = Clock loss
07 = Fire loop trouble
08 = Fail to communicate to monitoring station telephone #1
09 = Fail to communicate to monitoring station telephone #2
11 = Fail to communicate to voice report
12 = RF jamming
13 = GSM RF jamming
14 = GSM no service
15 = GSM supervision lost
99 = Any new trouble event
45 = Trouble restored 00 = Telephone line restored
01 = AC failure restore
02 = Battery failure restore
03 = Auxiliary current overload restore
04 = Bell current overload restore
05 = Bell disconnected restore
06 = Clock loss restore
07 = Fire loop trouble restore
08 = Fail to communicate to monitoring station telephone #1 restore
09 = Fail to communicate to monitoring station telephone #2 restore
11 = Fail to communicate to voice report restore
12 = RF jamming restore
13 = GSM RF jamming restore
14 = GSM no service restore
15 = GSM supervision lost restore
99 = Any trouble restored event
Event Group # Sub-group #

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 and is the answer not in the manual?

Paradox Magellan MG5050 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256
Built-in TransceiverYes
Remote ControlYes
Wireless KeypadsYes
StayD ModeYes
RemotesUp to 32
Power Supply16.5 VAC
Zones32
Battery Backup7Ah