Page
AC10 Inverter
7.7.7 Application of Power Line Filter ......................................................... 7-13
Chapter 8 Operation and Simple Running ............................................................................ 8-1
8.1 Basic Conception ............................................................................ 8-1
8.1.1 Control Mode ....................................................................................... 8-1
8.1.2 Mode of Torque Compensation ........................................................... 8-1
8.1.3 Mode of frequency setting ................................................................... 8-1
8.1.4 Mode of controlling for running command........................................... 8-1
8.1.5 Operating status of inverter ................................................................. 8-1
8.2 Keypad Panel and Operation Method ............................................. 8-2
8.2.1 Method of operating the keypad panel ............................................ 8-2
8.2.2 Operation Process of Setting the Parameters using the Keypad Panel
8-2
8.2.3 Setting the Parameters .................................................................... 8-2
8.2.4 Switching and displaying of status parameters ............................... 8-2
8.2.5 Switching of the parameters displayed under stopped status ......... 8-3
8.2.6 Switching of the parameters displayed under running status ......... 8-3
8.2.7 Operation process of measuring motor parameters ....................... 8-3
8.2.8 Operation process of simple running .............................................. 8-4
8.3 Illustration of Basic Operation ......................................................... 8-5
8.3.1 Frequency setting, start, forward running and stop using the keypad
panel 8-5
8.3.2 Setting the frequency using the keypad panel, and starting, forward
and reverse running, and stopping inverter through control terminals ........ 8-6
8.3.3 Operation process of jogging operation using the keypad panel .... 8-7
8.3.4 Setting the frequency with analog terminal and controlling the
operation with control terminals ................................................................... 8-8
Chapter 9 Function Parameters ........................................................................................... 9-1
9.1 Basic Parameters ............................................................................ 9-1
9.2 Operation Control ....................................................................................... 9-11
9.3 Multifunctional Input and Output Terminals ............................................... 9-19
9.3.1 Digital multifunctional output terminals ............................................. 9-19
9.3.2 Digital multifunctional input terminals ................................................ 9-22
9.3.3 Analog input monitoring .................................................................. 9-26
9.4 Analog Input and Output ............................................................... 9-27
9.5 Multi-stage Speed Control ............................................................. 9-31
9.6 Auxiliary Functions ........................................................................ 9-33
9.7 Malfunction and Protection ............................................................ 9-37
9.8 Motor Parameters .......................................................................... 9-42
9.9 Communication Parameter............................................................ 9-45
9.10 PID Parameters ............................................................................. 9-45
9.11 Torque Control Parameters ........................................................... 9-48
TC-Hydraulik - Rsdorfer Str. 8 - 25746 Heide - Lars Lornsen - T: +49 481 909 - 34 - l.lornsen@tc-hydraulik.de - www.tc-hydraulik.de

Table of Contents

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking