EasyManua.ls Logo

Parker COMPAX-M /-S (L) - Page 152

Parker COMPAX-M /-S (L)
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
COMPAX-M / -S
Digital inputs and outputs
152
If MZ travel is interrupted by the synchronous stop, then O3 "Machine zero
approached" is not output.
P219 = xx000000=0: COMPAX-M does not evaluate the additional emergency
stop input.
(Additional emergency stop input: X9/5-X9/6 (front plate);
COMPAX-M only)
P219 = xx000111=7: Emergency stop with P10 as relative ramp time, then switch
off, message E56, display E56, output O1 = 0, ready contact
removed.
Also effective in programming mode!
Note for MZ travel:
Additional
assignment of
P219: