EasyManuals Logo

Parker EX Series User Manual

Parker EX Series
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38 Pvd3665_Gb_Ex_August 2022
2.4. General Technical Data for ATEX/IECEx motors
EX3, EX4, EX6
EX8
Motor type
Permanent-magnet synchronous motor
Magnets material
Neodymium Iron Boron
Number of poles
10
Type of
construction
IMB5 IMV1 IMV3 (EN60034-7)
Degree of
protection
Gazeous atmosphere : IP64 on request, IP65
Combustible dust atmosphere : IP65
Cooling
Natural cooling
Rated voltage
230VAC, 400 VAC
Insulation of the
stator winding
Class F according to
IEC 60034-1
Class F according to IEC 60034-1
with potting
Altitude
Up to 1000m (IEC 60034-1)
No allowed for higher altitude
Ambiant
temperature
-20°C to +40°C
-20°C to +60°C with performances derating
Storage
temperature
-20°C to +60°C
Connection
Electronic plate with cable glands
Marking
CE and IECEx
Paint
Black RAL9005
Sensor
Resolver as a standard
Sick encoder Hiperface & DSL
SKS36 and SKM36 SIL2
EKS and EKM36 SIL2
Sensorless
Brake
Parking brake as an option
Thermal
protection
Thermoswitches + thermofuse
Remark
Numerous customization are possible on request (special shaft,
special flange,…)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker EX Series and is the answer not in the manual?

Parker EX Series Specifications

General IconGeneral
Fuel TypeGasoline
Control TypeElectronic
Valves per Cylinder4
Fuel SystemFuel Injected
Bore x Stroke86 mm x 86 mm

Related product manuals