5.3. Integration constraints
Location of a water treatment system is important. The following conditions are required:
• level platform or floor;
• room to access equipment for maintenance and adding brine (salt) to tank;
• constant electrical supply to operate the controller;
• total minimum pipe run to water heater of 3 m (10 ft) to prevent backup of hot water into system;
• always install check valve to protect the softener from hot water return;
• local drain for discharge as close as possible;
• water line connections with shut off or bypass valves;
• must meet any local and state codes for site of installation;
• valve is designed for minor plumbing misalignments. Do not support weight of system on the
plumbing;
• be sure all soldered pipes are fully cooled before attaching plastic valve to the plumbing.