ID2 Code, extended ID2 code
The ID2 code is set by the slave manufacturer and cannot be changed. The AS-i
Association determines the ID2 codes, which are assigned for a particular class of
slaves. For example, all 2-channel 16 bit input slaves having an S-7-3 bit code
use ID2 code “D”. Since this code was not introduced until AS-i Specification 2.1,
it is also referred to as extended ID2 code.
Current configuration
The configuration data of all slaves detected by the master. The configuration
data of a slave, the slave profile, consists of:
IO code, ID code, extended ID1code , extended ID2 code.
Current parameter
The AS-i parameter that have most recently been sent to the AS-i slave, as op-
posed to permanent parameters.
Configuration Error/Config Error
An configuration error is displayed if the target and the current configuration of the
connected slaves do not match. A configuration error could be due to the follow-
ing:
Missing slave:A slave entered in the LPS is not available
Wrong type of slave:The slave profile of the connected slave does not comply
with the configuration.
Unknown slave: A connected slave is not entered in the LPS.
LAS - List of Activated Slaves
The master exchanges I/O data with the slaves entered in the LAS. In protected
mode only the detected slaves (
LDS) that are expected by the master and are
entered in the
LPS are activated. In configuration mode all slaves entered in
the
LDS are activated.
LDS - List of Detected Slaves
If the master was able to read the
slave profile, the slave is entered in the LDS.
LPF - List of Peripheral Faults
The list of peripheral faults was introduced with specification 2.1. This list includes
an entry for each slave that signals a
peripheral fault.
LPS - List of Projected Slaves
The list of projected slaves includes all slaves expected by the master. When sav-
ing the current configuration all entries in the
LDS are stored in the LPS (ex-
cept for a slave with address 0).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepperl+Fuchs AS-I 3.0 PROFIBUS and is the answer not in the manual?

Pepperl+Fuchs AS-I 3.0 PROFIBUS Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelAS-I 3.0 PROFIBUS
CategoryGateway
LanguageEnglish

Related product manuals