Adjustment
13 - 41
200 210 Turn-on time air jet [s] 0 - 10 1
400 401 Raise clamp delay 0.0 - 1.5 s 0.0s
402 Start delay after clamp lowered 0.0 - 1.5 s 0.0 s
403 Delay before thread trimming 0.0 - 2.0 s 0.0 s
Interval before thread wiper
started 0.0 - 2.0 s 0.06 s
404 Thread cutting time or waiting time 0.0 - 2.0 s 0.06 s
Thread wiper forward
405 Waiting time for thread clamp (s) 0.00 – 2.00 0.10
406 Waiting time for thread puller (s) 0.00 – 2.00 0.20
407 Waiting time until thread wiper in basic
position 0.00 – 4.00 0.20
408 Waiting time for pressure release
added feature clamp / insert plate (s) 0.00 - 1.5 s 1
500 501 Soft start stitches 0 - 15 1
Soft start speed (spm) 500 - 2000 500
503 Extra stitches when sewing in 0 - 3 0
same hole
504 Delay time thread clamp open at
beginning of seam 0 – 2s 0,02s
506 Angle position for "end knotting on" 0 – 127 36
507 Angel position for "end knotting off" 0 – 127 52
508 Number of stitches for "thread clamp 0 – 3 0
closed"at end of seam (calculated
backwards from the last stitch)
Angle position for "thread clamp
closed" at end of seam 0 – 127 80
510 Angle position for "thread clamp open" 0 – 127 120
at last needle penetration before thread
trimming
511 Securing stitches before cutting 0 – 2 0
512 Measuring point of missed stitch 0 - 127 115 incr.
detection function with display of the
thread strength
513 Angle setting for "material shift on" 0 - 127 85
Group Parameter Description Setting Set value