E. Check the crankshaft:
1.measure the clearance between crank
shaft and co-rod big end.(Parallel
direction to rod)
2.check the looseness on X.Y. axis of the connecting rod big end(Perpendicular directions to rod)
Limit of use: Replace a new when above 0.71mm
Limit of use: Replace a new one when above 0.04mm