Analysis
Analyzer - CIE Chart
[PHQXO-HDR]
The CIE 1931 x y chart provides a display of signal chromaticity - complete with Rec. 709, Rec. 2020, ST
2086 gamut overlays and the Illuminant D65 white point reference.
CIE Chart setup is accessed by right-clicking within the chart area:
l Rec.709 Triangle > [Enabled, Disabled]
l Rec.2020 Triangle > [Enabled, Disabled]
l ST 2086 Triangle > [P3, Disabled]
l D65 White Point > [Enabled, Disabled]
l Single Line Mode > [Enabled, Disabled]
l Single Line Mode > Enabled > Line Number > [1 to Total no. of Active Lines for current standard]
l Zoom > [slider 1.00...4.00]
l Zoom > x Position > [slider, left to right]
l Zoom > y Position > [slider, bottom to top]
l Brightness > [slider 1..31]
l Gamma > [slider 1..255]
l Persistence [slider 1..255]
l S-Log3 Mode [S-Log3, SR Live]
Zoom can also be performed by hovering the mouse crosshairs over the chart and scrolling the mouse wheel.
Panning, in the x and y axes can also be performed by hovering the mouse crosshairs over the axis in question
and scrolling the mouse wheel.
Page 36 PHABRIX Qx User Manual