Qx Setup
From the ‘Qx Network & Automation’ window, enable ‘REST API’ in the submenu.
When enabled, the REST API setting will show the port number (8080) the Qx is listening on.
Connecting to the Qx via REST API
Run your chosen REST API client application on the computer you will use to connect to the Qx.
A connection to the Qx can be made using the IP Address or mDNS Hostname (if mDNS is enabled on your
computer) of the Qx unit, together with the port number.
For connection to the Qx:
As a GET request; in the URL field of the REST API client, enter the Qx address using the specific IP Address
or mDNS Hostname of your unit, in one of the following formats:
l http://192.168.0.70:8080/api
l http://qx-020094.local:8080/api
See Qx Network & Automation’ section of this manual, for an overview of Qx GET and PUT requests for
REST API.
Contact PHABRIX for full details of all available Qx REST API requests.
PUT, GET, DELETE, and POST requests can be scripted for automated testing use.
SFTP
Retrieval of Event Log, Preset, Screenshot, and User Test Pattern files, deletion of these files, plus the
addition of saved presets from another unit and user test patterns can be carried out using Secure File
Transfer Protocol (SFTP).
Connecting to the Qx via SFTP
Run your chosen SFTP client application on the computer from which you will connect to the Qx (your SFTP
server).
Enter the Qx host address using the specific IP Address of your Qx or its mDNS Hostname (if mDNS is
enabled on your computer), in one of the following formats:
l sftp://192.168.0.70
l sftp://qx-020094.local
Additionally, provide the following:
Username: qxuser; Password: phabrixqx; Port: 22
Once connected, open the ‘transfer’ directory to access the ‘log (for the Event Log), ‘presets’, ‘screenshots’,
and 'userTestPatterns' folders. Files can be downloaded, deleted and added (in the case of ‘presets’ and
'userTestPatterns') to these folders as required.
Web Browser
A web browser can be used to view Event Log, Screenshot, Preset, and User Test Patterns files, and
retrieve them.
Connecting to the Qx via web browser
In the web browser of your choice on your computer, enter the IP address of your Qx, in the following format:
l http://192.168.0.70
Once connected, access the ‘logs’, ‘presets’, ‘screenshots’, and 'userTestPatterns' folders as required. View
and save files to your computer as required.