0.9 BDL3245E/BDL4245E/BDL4645E
32”/42”/46” FHD LCD PUBLIC DISPLAY
2011-07-01 PHILIPS Page 10 of 38
MMD Con
f
idential
z Recovery from DPM - Power & function recover when either H & V syncs or digital
clock are detected.
z Sleeping - The Display enters “sleeping mode” when there is no HDMI(Video
mode)AV(Composite, Component) signal input in 30 minutes; the display will
enter “sleeping mode” when no PC signals(D-sub, DVI, HDMI(PC mode)) for 20
seconds.
z Standby - RC/Keypad switch off
z Recovery from Standby – RC/Keypad switch on
2.5.4 SURGE IMMUNITY
1 Surge immunity for power line
1-1 Purpose:
The purpose of this test is to make sure the power circuit can protect lighting surge when the
noise occurred.
1-2 Test Equipment:
(1) NOISEKEN LSS-5S, LSS-15SC or equivalent
* Variable range of voltage: +/-6KV
* Surge waveform: Voltage surge 1.2/50µs
(2) AC power supply
(3) Signal generator
(4) Test equipment for insulation resistance & dielectric strength
1-3 Test Condition:
Power Supply: 120V/60Hz, 230V/50Hz
1-4 Test Method:
(1) The wave form refers to EN61000-4-5(IEC61000-4-5)
(2) Using Combination Waveform
Voltage Surge Wave: 1.2/50µsec.
Trigger Phase: 90°, 270°
Insulation Resistance (1)/ (2): L1+L2 to SG, 500V (DC)
Test 1
Surge Point Voltage Time EUT Status
Line1 to Line2 ±1kV 5 Power ON, Input signal
Line1 to GND ±2kV 5 Power ON, Input signal
Line2 to GND ±2kV 5 Power ON, Input signal